Current Transformers
High specification line of current transformers. Custom built in-house, our high accuracy industrial split-core, solid-core and flexible current transformers are among the industry's highest specification CT and offer exceptional value.
![AcuCT Flex product image.](http://accucdn.accuenergy.com/wp-content/uploads/All-CT-Product-Tab-AcuCT-Flex-Coil-200x200-1.png)
![UL Recognized Cert.](http://accucdn.accuenergy.com/wp-content/uploads/ul-recognized.png)
![CE Cert.](http://accucdn.accuenergy.com/wp-content/uploads/ce-mark.png)
![ROHS Cert.](http://accucdn.accuenergy.com/wp-content/uploads/rohs-compliant.png)
ROGOWSKI COIL
AcuCT Flex Series
Flexible current transformer designed to easily fit into tight spaces. Non-invasive in design & high accuracy 0.5% rated, it has a wide current sensor range between 5A-50,000A & frequency response range 10Hz-20kHz for harmonics detection. Compatible with any third-party meters or Accuenergy meters.
![AcuCT R product image.](http://accucdn.accuenergy.com/wp-content/uploads/All-CT-Product-Tab-AcuCT-R-200x200-1.png)
![UL Listed Cert.](http://accucdn.accuenergy.com/wp-content/uploads/ul-listed.png)
![CE Cert.](http://accucdn.accuenergy.com/wp-content/uploads/ce-mark.png)
![ROHS Cert.](http://accucdn.accuenergy.com/wp-content/uploads/rohs-compliant.png)
SPLIT-CORE CURRENT TRANSFORMERS
AcuCT R Series
Revenue grade, IEC 60044-1 0.5s class split-core AC current transformer with multiple window sizes & many output rating choices including 80mA, 333mV, & 5A. Use on services from 5A-5000A (depending on model). Split-core form factor simplifies installation. UL Listed for XOBA UL2808 Standard.
![AcuCT 5A product image.](http://accucdn.accuenergy.com/wp-content/uploads/All-CT-Product-Tab-AcuCT-5A-200x200-1.png)
![UL Recognized Cert.](http://accucdn.accuenergy.com/wp-content/uploads/ul-recognized.png)
![CE Cert.](http://accucdn.accuenergy.com/wp-content/uploads/ce-mark.png)
![ROHS Cert.](http://accucdn.accuenergy.com/wp-content/uploads/rohs-compliant.png)
SPLIT-CORE CURRENT TRANSFORMERS
AcuCT 5A Series
Revenue grade, IEC 60044-1 0.5s class split-core AC current transformer. Four sizes available with choice of 1A or 5A output for industrial applications. Use on services from 5A-5000A (depending on model). Split-core design simplifies installation without conductor disconnection.
![AcuCT mV product image.](http://accucdn.accuenergy.com/wp-content/uploads/All-CT-Product-Tab-AcuCT-mV-3050-200x200-1.png)
![UL Recognized Cert.](http://accucdn.accuenergy.com/wp-content/uploads/ul-recognized.png)
![CE Cert.](http://accucdn.accuenergy.com/wp-content/uploads/ce-mark.png)
![ROHS Cert.](http://accucdn.accuenergy.com/wp-content/uploads/rohs-compliant.png)
SPLIT-CORE CURRENT TRANSFORMERS
AcuCT mV Series
Revenue grade, IEC 60044-1 0.5s class split-core AC current transformer. Four sizes available, each with a safe 333mV output. For use on services from 20A-5000A (depending on model). Split-core design accelerates installation without conductor disconnection.
![AcuCT Hinged product image.](http://accucdn.accuenergy.com/wp-content/uploads/All-CT-Product-Tab-AcuCT-Hinged-200x200-1.png)
![UL Recognized Cert.](http://accucdn.accuenergy.com/wp-content/uploads/ul-recognized.png)
![CE Cert.](http://accucdn.accuenergy.com/wp-content/uploads/ce-mark.png)
![ROHS Cert.](http://accucdn.accuenergy.com/wp-content/uploads/rohs-compliant.png)
SPLIT-CORE CURRENT TRANSFORMERS
AcuCT Hinged Series
Hinged split-core AC current transformer with 0.5% high accuracy measurements. Four sizes available, each with a safe 333mV output. Use on services from 5A-630A (depending on model). Compact form factor is superior in crowded panels & hinged split-core design promotes fast installation.
![AcuCT S77 product image.](http://accucdn.accuenergy.com/wp-content/uploads/All-CT-Product-Tab-AcuCT-S77-200x200-1.png)
![UL Listed Cert.](http://accucdn.accuenergy.com/wp-content/uploads/ul-listed.png)
![CE Cert.](http://accucdn.accuenergy.com/wp-content/uploads/ce-mark.png)
![Measurement Canada Approved](http://accucdn.accuenergy.com/wp-content/uploads/measurement-canada-approved.jpg)
SOLID-CORE CURRENT TRANSFORMERS
AcuCT S77 Series
Measurement Canada approved, revenue grade 0.15 class solid-core AC current transformer. Use on 100A or 200A services & choose from 80mA or 100mA output. Solid-core design provides protection against dust or debris. UL Listed for UL2808 Standard.
![AcuCT S113 product image.](http://accucdn.accuenergy.com/wp-content/uploads/All-CT-Product-Tab-AcuCT-S113-200x200-1.png)
![UL Listed Cert.](http://accucdn.accuenergy.com/wp-content/uploads/ul-listed.png)
![CE Cert.](http://accucdn.accuenergy.com/wp-content/uploads/ce-mark.png)
![ROHS Cert.](http://accucdn.accuenergy.com/wp-content/uploads/rohs-compliant.png)
SOLID-CORE CURRENT TRANSFORMERS
AcuCT S113
Solid-core AC current transformer with 1% accuracy. Three input ratings available (200A, 300A, 400A) with 5A, 1A, 333mV rated industrial output. Rugged solid-core design is ideal for product integrations & general metering. UL Listed for UL2808 Standard.
![AcuCT S220 product image.](http://accucdn.accuenergy.com/wp-content/uploads/AcuCT-S220__3QR-200x200-1.png)
![UL Listed Cert.](http://accucdn.accuenergy.com/wp-content/uploads/ul-listed.png)
![CE Cert.](http://accucdn.accuenergy.com/wp-content/uploads/ce-mark.png)
![ROHS Cert.](http://accucdn.accuenergy.com/wp-content/uploads/rohs-compliant.png)
SOLID-CORE CURRENT TRANSFORMERS
AcuCT S220 Series
Switchgear solid-core current transformer with 1A, 5A, 80mA, 100mA, 333mV output rating and a wide selection of input ratings. Accuracy class: 0.5, 0.5S, 0.2 and window size Ø2.24” (Ø57.0 mm).
![AcuCT S335 product image.](http://accucdn.accuenergy.com/wp-content/uploads/AcuCT-S335__3QR-200x200-1.png)
![UL Listed Cert.](http://accucdn.accuenergy.com/wp-content/uploads/ul-listed.png)
![UL Recognized Cert.](http://accucdn.accuenergy.com/wp-content/uploads/ul-recognized.png)
![CE Cert.](http://accucdn.accuenergy.com/wp-content/uploads/ce-mark.png)
![ROHS Cert.](http://accucdn.accuenergy.com/wp-content/uploads/rohs-compliant.png)
SOLID-CORE CURRENT TRANSFORMERS
AcuCT S335 Series
Busbar solid-core current transformer with 1A, 5A, 80mA, 100mA, 333mV output rating and a wide selection of input ratings. Accuracy class: 0.5, 0.5S, 0.2 and window size Ø2.83” (Ø72.0 mm).
![AcuCT S433 product image.](http://accucdn.accuenergy.com/wp-content/uploads/AcuCT-S433__3QR-200x200-1.png)
![UL Listed Cert.](http://accucdn.accuenergy.com/wp-content/uploads/ul-listed.png)
![UL Recognized Cert.](http://accucdn.accuenergy.com/wp-content/uploads/ul-recognized.png)
![CE Cert.](http://accucdn.accuenergy.com/wp-content/uploads/ce-mark.png)
![ROHS Cert.](http://accucdn.accuenergy.com/wp-content/uploads/rohs-compliant.png)
SOLID-CORE CURRENT TRANSFORMERS
AcuCT S433 Series
Instrument solid-core current transformer with 1A, 5A, 80mA, 100mA, 333mV output rating and a wide selection of input ratings. Accuracy class: 0.5, 0.5S, 0.2 and window size Ø3.66” (Ø93.0 mm).
![AcuCT S650 product image.](http://accucdn.accuenergy.com/wp-content/uploads/AcuCT-S650__3QR-200x200-1.png)
![UL Listed Cert.](http://accucdn.accuenergy.com/wp-content/uploads/ul-listed.png)
![UL Recognized Cert.](http://accucdn.accuenergy.com/wp-content/uploads/ul-recognized.png)
![CE Cert.](http://accucdn.accuenergy.com/wp-content/uploads/ce-mark.png)
![ROHS Cert.](http://accucdn.accuenergy.com/wp-content/uploads/rohs-compliant.png)
SOLID-CORE CURRENT TRANSFORMERS
AcuCT S650 Series
Solid-core current transformer with 1A, 5A, 80mA, 100mA, 333mV output rating and a wide selection of input ratings. Accuracy class: 0.5, 0.5S, 0.2 and window size 6.30” (160.0 mm).
![HAB-16555 product image.](http://accucdn.accuenergy.com/wp-content/uploads/All-CT-Product-Tab-HAB-16555-DC-200x200-1.png)
![CE Cert.](http://accucdn.accuenergy.com/wp-content/uploads/ce-mark.png)
![ROHS Cert.](http://accucdn.accuenergy.com/wp-content/uploads/rohs-compliant.png)
DC SENSOR
HAB-16555
Split-core DC current sensor with 0.5% accuracy. Available with one of five input ratings & either 4-20mA or 0-5AV output. Unidirectional & bidirectional models available. Non-invasive, split-core design can be easily integrated into existing installations.
![HAK product image.](http://accucdn.accuenergy.com/wp-content/uploads/All-CT-Product-Tab-HAK-40-200x200-1.png)
![CE Cert.](http://accucdn.accuenergy.com/wp-content/uploads/ce-mark.png)
![ROHS Cert.](http://accucdn.accuenergy.com/wp-content/uploads/rohs-compliant.png)
DC SENSOR
HAK Series
Split-core DC current sensor with 0.5% accuracy. Two sizes available eith either 4-20mA or 0-5V rated output. Measure up to 1000A DC current (depending on model). Unidirectional & bidirectional models available. Compact split-core design facilitates fast, non-intrusive installation.
![DC Shunt product image.](http://accucdn.accuenergy.com/wp-content/uploads/All-CT-Product-Tab-DC-Current-Shunt-200x200-1.png)
![ROHS Cert.](http://accucdn.accuenergy.com/wp-content/uploads/rohs-compliant.png)
DC SHUNT
DC Shunt Series
DC current shunts with 0.1 - 0.5% accuracy range. Multiple sizes & input ratings (depending on model) each with a voltage drop of 75mV. High-precision resistor provides reliable measurements in any DC current system.
![HV2 product image.](http://accucdn.accuenergy.com/wp-content/uploads/All-CT-Product-Tab-HV2-200x200-1.png)
![ROHS Cert.](http://accucdn.accuenergy.com/wp-content/uploads/rohs-compliant.png)
HV2
HV2 Series
Surface mount voltage sensor with 0.5% accuracy. Choose from 1000V, 1200V, or 1500V input rating to measure DC voltage across a wide frequency range. High immunity to interference maintains performance in harsh environments. Compatible with DC power meters.
![RIK 1AR product image.](http://accucdn.accuenergy.com/wp-content/uploads/AcuCT-C__3QR-200x200-1.png)
![CE Cert.](http://accucdn.accuenergy.com/wp-content/uploads/ce-mark.png)
![ROHS Cert.](http://accucdn.accuenergy.com/wp-content/uploads/rohs-compliant.png)
![Measurement Canada Approved](http://accucdn.accuenergy.com/wp-content/uploads/measurement-canada-approved.jpg)
CT CONVERTER
AcuCT C
5A:80mA/100mA current transformer converter. IEEE Std C57.13-2016 0.15 accuracy class, ratio error < 0.5%, and phase error < 8'.
![RIK 1AR product image.](http://accucdn.accuenergy.com/wp-content/uploads/All-CT-Product-Tab-RIK-1AR-200x200-1.png)
![UL Listed Cert.](http://accucdn.accuenergy.com/wp-content/uploads/ul-listed.png)
![CE Cert.](http://accucdn.accuenergy.com/wp-content/uploads/ce-mark.png)
![ROHS Cert.](http://accucdn.accuenergy.com/wp-content/uploads/rohs-compliant.png)
ROGOWSKI INTEGRATOR
RIK 1AR Series
Protective Relay Class Integrator pairs with Rogowski coils for any devices that require 1A nominal CT input. It allows for five field-configurable CT ratios between 2.5A-100,000A. Works in both 50Hz and 60Hz systems. AcuCT Flex Rogowski coils and the power supply are sold separately.
![RIK 5A product image.](http://accucdn.accuenergy.com/wp-content/uploads/All-CT-Product-Tab-RIK-A5-200x200-1.png)
![UL Listed Cert.](http://accucdn.accuenergy.com/wp-content/uploads/ul-listed.png)
![CE Cert.](http://accucdn.accuenergy.com/wp-content/uploads/ce-mark.png)
![ROHS Cert.](http://accucdn.accuenergy.com/wp-content/uploads/rohs-compliant.png)
ROGOWSKI INTEGRATOR
RIK 5A Series
Integrator kit comes with Rogowski coils for any devices/meters that require 0-5A nominal CT input. It allows for seven field-configurable CT ratios between 2.5A-50,000A. Works in both 50Hz and 60Hz systems. Can be used in 1-phase or 3-phase systems. Includes AcuCT Flex Rogowski coils.
![RIK mV product image.](http://accucdn.accuenergy.com/wp-content/uploads/All-CT-Product-Tab-RIK-mV-200x200-1.png)
![UL Listed Cert.](http://accucdn.accuenergy.com/wp-content/uploads/ul-listed.png)
![CE Cert.](http://accucdn.accuenergy.com/wp-content/uploads/ce-mark.png)
![ROHS Cert.](http://accucdn.accuenergy.com/wp-content/uploads/rohs-compliant.png)
ROGOWSKI INTEGRATOR
RIK mV Series
Integrator pairs with Rogowski coils for any devices/meters that require 333mV CT input. It allows for seven field-configurable CT ratios between 2.5A-50,000A. Works in both 50Hz and 60Hz systems. Choice between 1-phase or 3-phase. Rogowski coils and power supply sold separately.
![RIK mA product image.](http://accucdn.accuenergy.com/wp-content/uploads/All-CT-Product-Tab-RIK-mA-200x200-1.png)
![UL Listed Cert.](http://accucdn.accuenergy.com/wp-content/uploads/ul-listed.png)
![CE Cert.](http://accucdn.accuenergy.com/wp-content/uploads/ce-mark.png)
![ROHS Cert.](http://accucdn.accuenergy.com/wp-content/uploads/rohs-compliant.png)
ROGOWSKI INTEGRATOR
RIK mA Series
Integrator pairs with Rogowski coils for any devices/meters that require 4-20mA or 0-20mA CT input. It allows for seven field-configurable CT ratios between 2.5A-50,000A. Works in both 50Hz and 60Hz systems. Choice between 1-phase or 3-phase. Rogowski coils and power supply sold separately.
![RIK V product image.](http://accucdn.accuenergy.com/wp-content/uploads/All-CT-Product-Tab-RIK-V-200x200-1.png)
![UL Listed Cert.](http://accucdn.accuenergy.com/wp-content/uploads/ul-listed.png)
![CE Cert.](http://accucdn.accuenergy.com/wp-content/uploads/ce-mark.png)
![ROHS Cert.](http://accucdn.accuenergy.com/wp-content/uploads/rohs-compliant.png)
ROGOWSKI INTEGRATOR
RIK V Series
Integrator pairs with Rogowski coils for any devices/meters that require 0-5V or 0-10V CT input. It allows for seven field-configurable CT ratios between 2.5A-50,000A. Works in both 50Hz and 60Hz systems. Choice between 1-phase or 3-phase. Rogowski coils and power supply sold separately.
Contact Our
Product Expert
Comparison Table | ![]() AcuCT Flex | ![]() RIK 1AR1AR Rogowski | ![]() RIK 5A5A Rogowski | ![]() RIK mV333mV Rogowski | ![]() RIK 4-20 mA4-20mA or 0-20mA Rogowski | ![]() RIK 0-5V0-5V / 0-10V Rogowski |
---|---|---|---|---|---|---|
Location | Panel / Device / Circuit / Bus | Panel / Device / Circuit / Bus | Panel / Device / Circuit / Bus | Panel / Device / Circuit / Bus | Panel / Device / Circuit / Bus | Panel / Device / Circuit / Bus |
Form Factor | Flexible Rope-Like CT | Flexible Rope-Like CT* | Flexible Rope-Like CT | Flexible Rope-Like CT* | Flexible Rope-Like CT* | Flexible Rope-Like CT* |
Application | High Accurancy Power Quality Tenant Metering Tight Spaces | Protection Relay Tight Spaces | High Accurancy Power Quality Tenant Metering Tight Spaces | High Accurancy Power Quality Tenant Metering Tight Spaces | High Accurancy Power Quality Tenant Metering Tight Spaces | High Accurancy Power Quality Tenant Metering Tight Spaces |
Input Rated Option | 1-50kA | 50A, 200A, 500A, 2000A and 5000A | 500A, 1000A, 2500A, 5000A, 10000A, 25000A and 50000A | 500A, 1000A, 2500A, 5000A, 10000A, 25000A and 50000A | 500A, 1000A, 2500A, 5000A, 10000A, 25000A and 50000A | 500A, 1000A, 2500A, 5000A, 10000A, 25000A and 50000A |
Output Rated Options | mV | 0 - 1A | 0 – 6A RMS (0 – 5A RMS Nominal) | 0-333mVac | 4-20mAdc, 0-20mAdc | 0-5Vdc, 0-10Vdc |
Measurement Range | 50,000A | 0.25A – 100000A | 2.5A – 60000A | 2.5A – 60000A | 2.5A – 60000A | 2.5A – 60000A |
Accuracy | 0.5% | 1% at 1A, 5% at 20A | 1% | 1% | 1% | 1% |
Min. Window Size (in) | 4.17 | 4.17 | 4.17 | 4.17 | 4.17 | 4.17 |
Max. Window Size (in) | 14.5 | 14.5 | 14.5 | 14.5 | 14.5 | 14.5 |
UL Listed | ||||||
CE | ||||||
UL Recognized | ||||||
RoHS |
* Rogowski coil sold separately.
Comparison Table | ![]() AcuCT R | ![]() AcuCT 5A | ![]() AcuCT mV | ![]() AcuCT Hinged |
---|---|---|---|---|
Location | Panel / Device / Circuit / Bus | Panel / Device / Circuit / Bus | Panel / Device / Circuit / Bus | Branch Circuits |
Form Factor | Square/Rectangle Press Open | Square/Rectangle Removable Face | Rectangle Removable Face | Mini CT Hinged Opening |
Application | High Accurancy Power Quality Tenant Metering | General Use 5A/1A | General Use 333mV | Branch Circuit Monitoring |
Input Rated Option | 50A, 100A, 150A, 200A, 250A, 300A, 400A, 600A, 800A, 1000A, 1200A, 1500A,1600A, 2000A, 2500A, 3000A, 4000A, 5000A | 100A, 200A, 300A, 400A, 600A, 800A, 1000A, 1200A, 1500A, 2000A, 3000A, 5000A | 200A, 250A, 300A, 400A, 600A, 800A, 1000A, 1200A, 1600A, 2000A, 2500A, 3000A, 4000A, 5000A | 5A, 20A, 30A, 40A, 50A, 60A, 100A, 120A, 150A, 200A, 250A, 400A, 600A |
Output Rated Options | 333mV, 5A, 1A, 80mA, 100mA, 200mA | 5A, 1A | 333mV | 333mV |
Measurement Range | 5000A | 5000A | 5000A | 600A |
Accuracy | 0.5% | 0.5% | 0.5% | 0.5% |
Min. Window Size (in) | 0.75 x 0.75 | 0.83 x 1.22 | 0.75 x 0.75 | 0.4 |
Max. Window Size (in) | 5 x 7 | 3 x 5 | 3.1 x 6.3 | 1.38 |
UL Listed | ||||
CE | ||||
UL Recognized | ||||
RoHS |
Comparison Table | ![]() AcuCT S77Solid-Core CT | ![]() AcuCT S113Solid-Core CT | ![]() AcuCT S220Solid-Core CT | ![]() AcuCT S335Solid-Core CT | ![]() AcuCT S433Solid-Core CT | ![]() AcuCT S650Solid-Core CT |
---|---|---|---|---|---|---|
Location | Branch Circuits | Panel / Cable / Busbar | Switchgear / Panel / Cable / Busbar | Switchgear / Panel / Cable / Busbar | Switchgear / Panel / Cable / Busbar | Switchgear / Panel / Cable / Busbar |
Form Factor | Round | Round | Rectangle | Rectangle | Rectangle | Rectangle |
Application | Revenue Metering, branch circuit monitoring | Panel and Switchgear Manufacturing | Panel and Switchgear Manufacturing | Panel and Switchgear Manufacturing | Panel and Switchgear Manufacturing | Panel and Switchgear Manufacturing |
Input Rated Option | 100A, 200A | 200A, 300A, 400A | 300A, 500A, 600A, 800A, 1000A, 1200A, 1500A | 500A, 600A, 800A, 1000A, 1200A, 1500A, 2000A, 2500A, 3000A | 800A, 1000A, 1500, 2000A, 2500A, 3000A, 3500A, 4000A | 800A, 1000A, 1500A, 2000A, 2500A, 3000A, 3500A, 4000A |
Output Rated Options | 80mA, 100mA | 5A, 1A, 333mV | 1A, 5A, 80mA, 100mA, 333mV | 1A, 5A, 80mA, 100mA, 333mV | 1A, 5A, 80mA, 100mA, 333mV | 1A, 5A, 80mA, 100mA, 333mV |
Measurement Range | 200A | 200A | 0-1500A | 0-3000A | 0-4000A | 0-4000A |
Accuracy | 0.15% | 1% | IEC 61869-2 0.5, 0.5S, 0.2 | IEC 61869-2 0.5, 0.5S, 0.2 | IEC 61869-2 0.5, 0.5S, 0.2 | IEC 61869-2 0.5, 0.5S, 0.2 |
Min. Window Size (in) | 0.78 | 1.20 | Ø2.24 | Ø2.83 | Ø3.66 | 6.30 x 6.30 |
Max. Window Size (in) | 0.78 | 1.20 | Ø2.24 | Ø2.83 | Ø3.66 | 6.30 x 6.30 |
UL Listed | Pending | |||||
CE | ||||||
UL Recognized | ||||||
RoHS |
Comparison Table | ![]() HAB-16555DC Current Sensors | ![]() HAKHall Effect Current Sensors | ![]() DC ShuntDC Current Shunts | ![]() HV2DC Voltage Sensor |
---|---|---|---|---|
Location | Busbar, Cable | Busbar, Cable | Busbar, Screw Fixation | Busbar, Screw Fixation |
Form Factor | Rectangle, removable face | Round, removable face | Inline installation | Surface Mount |
Application | DC metering; Busbar; Cable | DC metering; Cable | DC metering; Busbar; Cable | DC metering; Busbar; Cable |
Input Rated Option | 1000A, 2000A, 3000A, 4000A, 5000A | 50A, 100A, 200A, 400A, 600A, 1000A | 100A, 200A, 300A, 400A, 500A, 1000A, 2000A | 1000V, 1200V, 1500V |
Output Rated Options | 4-20mA, 0-5V | 4-20mA, 0-5V | 75mV | 0-5Vdc |
Measurement Range | 5000A | 1000A | 2000A | 1500V |
Accuracy | 0.5% | 0.5% | 0.1 - 0.5% | 0.5% |
Min. Window Size (in) | 6.50 x 2.17 | 0.83 | n/a | n/a |
Max. Window Size (in) | 6.50 x 2.17 | 0.83 | 1.58 | n/a |
CE | ||||
RoHS |