Mouseover to zoom-in
DC Shunt product images.
DC Shunt - Left view.
DC Shunt - Right view.
DC Shunt - Front view.
DC Shunt - Right quarter angle view.
ROHS Compliant

DC Current Shunt

Accuenergy DC current shunts are engineered for precision measurement in DC current systems. Shunts are designed to measure electrical currents based on a small voltage drop created across a high-precision resistor placed in series with a load. When connected to a DC power meter, DC current shunts provide accurate energy measurements in a variety of applications including renewable energy, mass transit, battery charging, electric vehicles, welding, heavy industrial environments, and OEM applications.

  • Accuracy class: 0.5%
  • Multiple current input options to choose from
  • 75mV rated output

About DC Current Shunt Series

What is a DC shunt?

A direct current (DC) shunt is a specific type of resistor designed to send a millivolt output to a meter, or other instrument, that is in proportion to the current flowing through the shunt. Comprised of two conductive metals on the sides and connected by a band of specialized metal, called manganin, the shunt is designed to be placed along the DC line in series and, when current is flowing, a small, proportional voltage drop can be detected. DC shunts are used in instances where the current that is being measured is too large to be measured directly by a panel meter or other instrument.

DC Shunt series models.

DC Current Shunt Models

Shunt-50A/75mV
Input Ratings
Voltage Drop
Accuracy
Exterior
DC Shunt 50A model. 50A 75mV 0.5% 0.98" x 4.72" x 0.87"
Shunt-50A/75mV
DC Shunt 50A model.
Input Ratings
Volatage Drop
Accuracy
Exterior
50A 75mV 0.5% 0.98" x 4.72" x 0.87"
Shunt-100A/75mV
Input Ratings
Voltage Drop
Accuracy
Exterior
DC Shunt 100A model.
100A 75mV 0.5% 0.91" x 4.29" x 0.43"
Shunt-100A/75mV
DC Shunt 100A model.
Input Ratings
Voltage Drop
Accuracy
Exterior
100A 75mV 0.5% 0.91" x 4.29" x 0.43"
Shunt-200A/75mV
Input Ratings
Voltage Drop
Accuracy
Exterior
DC Shunt 200A model.
200A 75mV 0.5% 0.83" x 4.59" x 0.85"
Shunt-200A/75mV
DC Shunt 200A model.
Input Ratings
Voltage Drop
Accuracy
Exterior
200A 75mV 0.5% 0.83" x 4.59" x 0.85"
Shunt-500A/75mV
Input Ratings
Voltage Drop
Accuracy
Exterior
DC Shunt 500A model.
500A 75mV 0.5% 1.81" x 4.88" x 0.85"
Shunt-500A/75mV
DC Shunt 500A model.
Input Ratings
Voltage Drop
Accuracy
Exterior
500A 75mV 0.5% 1.81" x 4.88" x 0.85"
Shunt-1000A/75mV
Input Ratings
Voltage Drop
Accuracy
Exterior
DC Shunt 1000A model.
1000A 75mV 0.5% 3.81" x 4.88" x 0.85"
Shunt-1000A/75mV
DC Shunt 1000A model.
Input Ratings
Voltage Drop
Accuracy
Exterior
1000A 75mV 0.5% 3.81" x 4.88" x 0.85"
Shunt-2000A/75mV
Input Ratings
Voltage Drop
Accuracy
Exterior
DC Shunt 2000A model.
2000A 75mV 0.5% 5.35" x 7.87" x 3.82"
Shunt-2000A/75mV
DC Shunt 2000A model.
Input Ratings
Voltage Drop
Accuracy
Exterior
2000A 75mV 0.5% 5.35" x 7.87" x 3.82"
Shunt-4000A/75mV
Input Ratings
Voltage Drop
Accuracy
Exterior
DC Shunt 4000A model.
4000A 75mV 0.5% 7.87" x 7.48" x 3.82"
Shunt-4000A/75mV
DC Shunt 4000A model.
Input Ratings
Voltage Drop
Accuracy
Exterior